Product Description:

Anritsu 54147A Network Analyzer, 10 MHz to 20 GHz

The Anritsu 54147A network analyzer is an instrument which measures the complex transmission and reflection characteristics of two-port devices in the frequency domain. It does this by sampling the incident signal, separating the transmitted and reflected waves, and then performing ratios that are directly related to the reflection and transmission coefficients of the two-port. Frequency is swept to rapidly obtain amplitude and phase information over a band of frequencies of interest.

Anritsu 54147A network analyzers utilize synthesized-frequency sources to provide a known test stimulus that can sweep across a range of frequencies or power levels. Anritsu 54147A network analyzers also can perform ratioed measurements (including phase), which require multiple receivers. The Anritsu 54147A can provide a wealth of knowledge about a device under test (DUT), including its magnitude, phase, and group-delay response.

Fast,accurate measurement
Crystal-based source
Built-in automation
Built-in floppy disk
Rugged,reliable chassis
High Dynamic Range
High Resolution
N (f) Output Connector

Performance Characteristics of the 54147A

Form Factor Benchtop
Type Scalar
Integral Signal Source Yes
Integral Test Set No
Source Minimum Frequency 0.01 GHz
Source Maximum Frequency 20 GHz
Source Frequency Resolution 100 kHz
Source Frequency Accuracy 0.00001 %
Output Impedance 50 Ohm
No. of Receiver Channels 2 ch
Minimum Dynamic Range 71 dB
Maximum Dynamic Range 71 dB

Programmability/Connectivity of the 54147A

User Interface Proprietary
Ports to Peripheral Devices GPIB
Test Pattern Storage 13 Patterns
Novram data storage Yes
Data Storage Type FDD

54147A Compliance

CE Compliance Compliant
UL Compliance Not compliant

54147A Power Requirements

Input Power Universal (Auto Sense and Switch)

54147A Physical Dimensions

  • Width: 16.77 in(.66 in)
  • Height: 6.97 in(.27 in)
  • Length: 18.74 in(.73 in)
  • Weight: 39.68 lbs(87.47 lb)

Options for 54147A

Option US List Price
54100A-16 / Option 16, +15 DC Supply for Millimeter Wave Source Modules (Available for models 20 GHz or lower). $780
54100A-25 / Option 25, Maintenance Manual (P/N: 10410-00166) No Charge
54100A-26 / Option 26, Extra Operation Manual and GPIB User's Guide (P/N: 10410-00141) $165
54100A-2A / Option 2A, 70 dB 20 GHz Step Attenuator (Models 54137A and 54147A) $2,850
54100A-5 / Option 5, Add Reference (R) Channel $1,005
54100A-6 / Option 6, Add External Leveling Capability $390
54100A-7 / Option 7, Internal Distance to Fault Software $3,895
54100A-8 / Option 8, Internal Relative Group Delay Software $5,190
54100A-98 / Z540/Guide 25 Calibration $705
54100A-99 / Premium Calibration $895

More Anritsu savings

Anritsu MS2038CAnritsu MS2038C Using Handheld Spectrum Analyzers to Find Hidden Signals
Agilent S412EAnritsu S412E: Upgrade to 6GHz for half the price
Anritsu MS2038CAnritsu MS2028C/38C VNA Master Series for easy field and flight line RCS tests
Anritsu MS2726CFree 7-day trial on new Anritsu MS2726C 43 GHz Handheld Spectrum Analyzer
Anritsu Government and Military Test Equipment Savings Catalog
Anritsu MT9083AGovernment-only Anritsu OTDR 15% off deal
Anritsu S412EFree 7-day trial on new Anritsu LMR Master S412E Handheld Cable and Antenna Analyzer
Anritsu MS272xC SeriesAnritsu's First Handheld Spectrum Analyzers with up to 43 GHz Frequency
Anritsu MS4640ANew High Performance VectorStar MS4640A Series Vector Network Analyzers
Win an Anritsu Transforming Cube
Anritsu MS2719BApplication Note: Using Advanced Limit Line Features
Anritsu MS2028BVNA Master 20 GHz High Performance Handheld Vector Network Analyzer
Anritsu S412DApplication Note: Mapping BER and Signal Strength of P25 Radio Systems Application Note
View Movie WiMAX Test
Anritsu MS2725CApplication Note: Using Handheld Spectrum Analyers to Find Hidden Signals
Anritsu MS2024BApplication Note: Practical Tips on Making Vector Voltmeter (VVM) Phase Measurements
Anritsu MS4640AApplication Note: Time Domain Measurements Using Vector Network Analyzers