Product Description:
Fluke - Precision 5520A/6-2-USMC Multi-Product Calibrator
- Source
- DC and AC voltage and current
- Multiple waveforms and harmonics
- Two simultaneous voltage/current outputs
- Simulate DC and AC power with phase control
- Resistance, capacitance, thermocouples and RTDs
- Measure
- Thermocouple temperature
- Humidity and pressure (with included probe and pressure modules)
- Calibrate
- Analog and digital meters up to 6 1/2 digits
- Thermocouple and RTD thermometers
- Process calibrators
- Data loggers, strip and chart recorders
- Wattmeters and power harmonics analyzers
- Current clamps and clamp meters
- Analog or digital handheld and bench oscilloscopes
- Panel meters and graphical multimeters
- Power meters, disturbance analyzers, power quality monitors, and other power quality related equipment
This NAVICP model (U.S. Marine Corps configuration) is delivered with:- Option 5500A-SC600: 600 MHz oscilloscope calibration
- Option 5500A/Coil: 50-turn current coil (calibrate clamp-type current meters)
- 5500A/Case: roll-aboard transit case
- Option 5500A/LEADS: test lead set
- Option 5500A/HPROBE: humidity measurement probe
- Option FLUKE-700PCK: pressure module calibration kit
- Option FLUKE-700PD7: dual-pressure module (-15/200 psi)
- Option FLUKE-700PTP: hand pump
- 5800A/TDP: 125 ps tunnel diode pulser
- Y8021: IEEE-488 shielded interface cable
Performance Characteristics of the 5520A/6-2-USMC
| Form Factor |
Benchtop |
| Type |
Multifunction |
| DC Volts Minimum Range |
0 V |
| DC Volts Maximum Range |
1000 V |
| DC Volts No. of Ranges |
6 QTY |
| DC Volts Range Steps |
1/10/100 |
| DC Volts Minimum Resolution |
0.01 uV |
| DC Volts Maximum Resolution |
1020 uV |
| DC Volts Basic 1 yr accuracy |
0.0018 % |
| AC Volts Minimum Range |
1 mV |
| AC Volts Maximum Range |
1020 V |
| AC Volts No. of Ranges |
6 QTY |
| AC Volts Range Steps |
1/10/100 |
| AC Volts Minimum Frequency |
10 Hz |
| AC Volts Maximum Frequency |
500 kHz |
| AC Volts Minimum Resolution |
1 uV |
| AC Volts Maximum Resolution |
10 mV |
| AC Volts Basic 1 Year Accuracy |
0.8 % |
| DC Current Minimum Range |
0 A |
| DC Current Maximum Range |
20.5 A |
| DC Current No. of Ranges |
8 QTY |
| DC Current Range Steps |
1/10/100 |
| DC Current Minimum Resolution |
1 nA |
| DC Current Maximum Resolution |
100 uA |
| DC Current Basic 1 yr accuracy |
0.1 % |
| AC Current Minimum Range |
29 uA |
| AC Current Maximum Range |
20.5 A |
| AC Current No. of Ranges |
7 QTY |
| AC Current Range Steps |
1/10/100 |
| AC Current Minimum Resolution |
0.1 uA |
| AC Current Maximum Resolution |
5000 uA |
| Resistance Minimum Range |
0 Ohm |
| Resistance Maximum Range |
1100 MOhm |
| Resistance No. of Ranges |
17 QTY |
| Resistance Range Steps |
1/10/100 |
| Resistance Minimum Resolution |
0.0001 Ohm |
| Resistance Maximum Resolution |
10000 Ohm |
| Resistance Basic 1 yr accuracy |
1.5 % |
| Minimum Frequency |
0.01 Hz |
| Maximum Frequency |
600 MHz |
| Frequency Resolution |
0.01 Hz |
| Frequency Accuracy |
0.0025 % |
| Connector Type to DUT |
BNC,screw-post |
Programmability/Connectivity of the 5520A/6-2-USMC
| User Interface |
Proprietary
|
| Ports to Peripheral Devices |
IEEE-488 (GPIB), RS-232
|
5520A/6-2-USMC Compliance
| CE Compliance |
Compliant
|
| UL Compliance |
Compliant
|
| Safety Issue |
IEC 1010-1 (1992-1); ANSI/ISA-S82.01-1994;CAN/CSA-C22.2 No. 1010.1-92
|
5520A/6-2-USMC Power Requirements
| Input Power |
Universal (Auto Sense and Switch) |
5520A/6-2-USMC Physical Dimensions
- Width: 17.01 in(.66 in)
- Height: 7.01 in(.27 in)
- Length: 18.62 in(.73 in)
- Weight: 48.5 lbs(106.92 lb)