DC Power Supply


Overview

An electronic power supply, often referred to somewhat incorrectly as an AC adaptor, is an electronic device that produces direct current of a particular voltage and current from a source of electricity such as a battery or wall-socket power. The direct current (DC) is usually used to power the internal circuits of an electronic device, such as a computer.

A simple AC powered linear power supply uses a transformer to convert the alternating current from the wall to the desired voltage. An array of diodes then rectifies the alternating current to direct current. Finally, a low-pass filter smooths out the high-frequency ripple that is left after the rectification.

Important dc power supply products:

Manufacturer Model Condition Description Specs
TDK-Lambda Americas Inc. GEN30-50 New (GSA discount) Genesys - DC Power Supply: 1500W, 30V, 50A, 1U, Full Rack, AC Input: Single-phase 85-265VAC; AC Input Cable (USA): 2m, CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN30-50
TDK-Lambda Americas Inc. GEN30-333 New (GSA discount) Genesys - DC Power Supply: 10kW, 30V, 333A, 3U, Full Rack, AC Input: Three-phase 208VAC, 400VAC, or 480VAC; CE Mark: 10kW/15kW (400VAC/480VAC), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN30-333
TDK-Lambda Americas Inc. GEN30-25 New (GSA discount) Genesys - DC Power Supply: 750W, 30V, 25A, 1U, Full Rack, AC Input: Single-phase 85-265VAC; AC Input Cable (USA): 2m, CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN30-25
TDK-Lambda Americas Inc. GEN30-170 New (GSA discount) Genesys - DC Power Supply: 5kW, 30V, 170A, 2U, Full Rack, AC Input: Single-phase 230VAC or Three-phase 208VAC, 400VAC, or 480VAC; CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN30-170
TDK-Lambda Americas Inc. GEN30-110 New (GSA discount) Genesys - DC Power Supply: 3300W, 30V, 110A, 2U, Full Rack, AC Input: Single-phase 230VAC or Three-phase 208VAC, 400VAC, or 480VAC; CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN30-110
TDK-Lambda Americas Inc. GEN250-60 New (GSA discount) Genesys - DC Power Supply: 15kW, 250V, 60A, 3U, Full Rack, AC Input: Three-phase 208VAC, 400VAC, or 480VAC; CE Mark: 10kW/15kW (400VAC/480VAC), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN250-60
TDK-Lambda Americas Inc. GEN250-40 New (GSA discount) Genesys - DC Power Supply: 10kW, 250V, 40A, 3U, Full Rack, AC Input: Three-phase 208VAC, 400VAC, or 480VAC; CE Mark: 10kW/15kW (400VAC/480VAC), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN250-40
TDK-Lambda Americas Inc. GEN25-400 New (GSA discount) Genesys - DC Power Supply: 10kW, 25V, 400A, 3U, Full Rack, AC Input: Three-phase 208VAC, 400VAC, or 480VAC; CE Mark: 10kW/15kW (400VAC/480VAC), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN25-400
TDK-Lambda Americas Inc. GEN200-75 New (GSA discount) Genesys - DC Power Supply: 15kW, 200V, 75A, 3U, Full Rack, AC Input: Three-phase 208VAC, 400VAC, or 480VAC; CE Mark: 10kW/15kW (400VAC/480VAC), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN200-75
TDK-Lambda Americas Inc. GEN200-50 New (GSA discount) Genesys - DC Power Supply: 10kW, 200V, 50A, 3U, Full Rack, AC Input: Three-phase 208VAC, 400VAC, or 480VAC; CE Mark: 10kW/15kW (400VAC/480VAC), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN200-50
TDK-Lambda Americas Inc. GEN20-76 New (GSA discount) Genesys - DC Power Supply: 1500W, 20V, 76A, 1U, Full Rack, AC Input: Single-phase 85-265VAC; AC Input Cable (USA): 2m, CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN20-76
TDK-Lambda Americas Inc. GEN20-500 New (GSA discount) Genesys - DC Power Supply: 10kW, 20V, 500A, 3U, Full Rack, AC Input: Three-phase 208VAC, 400VAC, or 480VAC; CE Mark: 10kW/15kW (400VAC/480VAC), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN20-500
TDK-Lambda Americas Inc. GEN20-38 New (GSA discount) Genesys - DC Power Supply: 750W, 20V, 38A, 1U, Full Rack, AC Input: Single-phase 85-265VAC; AC Input Cable (USA): 2m, CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN20-38
TDK-Lambda Americas Inc. GEN20-250 New (GSA discount) Genesys - DC Power Supply: 5kW, 20V, 250A, 2U, Full Rack, AC Input: Single-phase 230VAC or Three-phase 208VAC, 400VAC, or 480VAC; CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN20-250
TDK-Lambda Americas Inc. GEN20-165 New (GSA discount) Genesys - DC Power Supply: 3300W, 20V, 165A, 2U, Full Rack, AC Input: Single-phase 230VAC or Three-phase 208VAC, 400VAC, or 480VAC; CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN20-165
TDK-Lambda Americas Inc. GEN16-310 New (GSA discount) Genesys - DC Power Supply: 5kW, 16V, 310A, 2U, Full Rack, AC Input: Single-phase 230VAC or Three-phase 208VAC, 400VAC, or 480VAC; CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN16-310
TDK-Lambda Americas Inc. GEN150-66 New (GSA discount) Genesys - DC Power Supply: 10kW, 150V, 66A, 3U, Full Rack, AC Input: Three-phase 208VAC, 400VAC, or 480VAC; CE Mark: 10kW/15kW (400VAC/480VAC), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN150-66
TDK-Lambda Americas Inc. GEN150-5 New (GSA discount) Genesys - DC Power Supply: 750W, 150V, 5A, 1U, Full Rack, AC Input: Single-phase 85-265VAC; AC Input Cable (USA): 2m, CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN150-5
TDK-Lambda Americas Inc. GEN150-34 New (GSA discount) Genesys - DC Power Supply: 5kW, 150V, 34A, 2U, Full Rack, AC Input: Single-phase 230VAC or Three-phase 208VAC, 400VAC, or 480VAC; CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN150-34
TDK-Lambda Americas Inc. GEN150-22 New (GSA discount) Genesys - DC Power Supply: 3300W, 150V, 22A, 2U, Full Rack, AC Input: Single-phase 230VAC or Three-phase 208VAC, 400VAC, or 480VAC; CE Mark (RoHS), Linking Cable (RS-485), RS-232/RS-485 Interface (NON CANCELLABLE or RETURNABLE) GEN150-22
Page:  1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19   20  21  22  23  24  25  26  27  28  29  30  31  32  33  34  35  36  37  38  39  40  41  42  43  44  45  46  47  48  49  50  51  52  53  54  55  56  57  58  59  60  61  62  63  64  65  66  67  68  69  70  71  72  73  74  75  76  77  78

DC Power Supplies by different manufacturers: